Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Application: | Electronic, Instrument, Position Sensor, Audio, Lighting, Harvesting Energy |
| Type: | Current Transformer |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency



Item | Specification |
Saturation Magnetic InductionBs(T) | ≥1.9 |
Electrical Resistivity (ρ)(μΩ·cm) | 50 |
Curie TemperatureTc (℃) | 740 |
Density ρ(g/cm3) | 7.65 |
Coercive Force Hc(Oe) | 0.5 |
Grade | Nominal Thickness | Theoretical Density | Core Loss(W/Kg) | Magnetic Induction(T) | ||
mm | Kg/dm 3 | P17/50 Typical Value | P17/50 Guaranteed Value | B8 Typical Value | B8 Guaranteed Value | |
B23P085 | 0.23 | 7.65 | 0.84 | 0.85 | 1.91 | 1.87 |
Notes: Magnetic measurement shall be conducted in accordance with GB/T 3655-2008. P17/50 refers to core loss at a frequency of 50 Hz and a maximum magnetic induction of 1.7 T. B8 refers to magnetic induction at a magnetizing field strength of 800 A/m. | ||||||